1. Product features:
- The constant voltage and constant voltage charging is safe and smooth, and the voltage and current sampling output of the device is controlled through the four-wire system connection for soft start, so as to make a safe and smooth transition in the constant voltage and constant voltage charging process to avoid the occurrence of peak damage to the
- Each CH can perform constant current and constant voltage charge and constant current discharge test on the 192 Cells that meet the voltage
- Impact form constant current to constant voltage switching, which is especially the requirement of lithium-ion battery charging
- Equipment and computer interface: the Ethernet interface between the equipment and computer can ensure the stability and real-time of remote data acquisition, and the operation of the equipment can be activated by the office network and remote monitoring workshop in real time.
- Each battery fully has its own constant current and constant voltage source, and its own loop does not affect each
- Real-time detection of each cell’s voltage, charging, the first constant current charging, when the battery voltage reaches the set value, will be smoothly transferred to constant voltage charging, to meet the set time or current termination conditions, the charge is over. During constant current discharge, discharge is completed and then the battery voltage is lower than the set value, the corresponding battery indicator lights
- Multiple conditions (capacity, time, open circuit voltage, discharge platform, etc.) for battery sorting;
- Automatically calculate the constant current charge ratio, capacity loss, discharge efficiency, average voltage, median voltage and other data;
- This equipment is to test battery charge, discharge and related characteristics. Through software programming, the operator can charge and discharge the battery with any current or voltage within testing
- Curve analysis and processing: curve analysis function. Can flexibly select the cycle that needs to be displayed, a variety of curve combinations (such as voltage, current, capacity- time;
- capacity-voltage; cycle times-charge-discharge end voltage and etc.); Graphics can be arbitrarily moved, horizontal/longitudinal magnified or reduced to check the voltage, current, capacity, cell voltage and other data details. Can compare one data file for different cycle data or compare several data file curves at one
1. Hardware Functions
No. | Function | Function Introduction |
1 |
Charging |
Constant-current charging (CC)
The channel is output by constant current with soft start, and no current impact occurs. Constant-voltage charging (CV) The channel is output by constant voltage without limiting the output current (the output current is restrained by the maximum current value of the device’s model). CC CV charging Restrain the output of voltage and current at the same time, and current hardware with soft start. No impact voltage and current during CC-CV transition. |
2 |
Discharging |
Constant-current discharging (CD)
The channel is output by constant current with soft start, and no current impact occurs. Constant-power discharging (CP) The channel is in constant power discharge mode, and the channel adjusts the current in real time according to the voltage of the battery port. Constant-voltage discharging The channel keeps the port battery voltage constant for discharge, and the current decreases gradually until the cut-off voltage is reached. |
3 | Standing (Rest) | Current circuit is cut off, without impact on data acquisition. |
4 | Stop | ⮚ Channel stopped completely
The circuit of the battery and the machine are completely cut off. |
Technical Specifications
No. | Item Name | Semco SI 5V 10A | |
1 | Channel numbers | 192 CH | |
2 |
Working mode for channel |
Charging: constant-current (CC), constant-voltage (CV), CC-CV (No impact voltage and current during CC-CV transition)
Discharging: constant-current (CD), constant-power (CP), constant-voltage. |
|
Stop conditions for channel | Time, total voltage, total current, capacity and etc. | ||
3 |
Channel voltage | Charging voltage | 0V-5V |
Discharging voltage | 2V-5V | ||
Accuracy | ±0.1%FS | ||
Resolution | 0.1mV | ||
Channel current | Testing range | ±10A |
Minimum output current |
20mA |
||
Accuracy | ±0.1%FS | ||
Efficiency | Discharging efficiency | 60% | |
4 |
Data exported mode |
Data exported as EXCEL and TXT files, as well as chart files, can be shown as data analysis waves for charging and discharging, voltage, capacity, current & time feature. | |
5 | Data saved mode | Data saving as file | |
6 | Cooling method | Air cooling | |
7 | Safety class | As per EN60950,GB4943 requirement. | |
Protection Class | IP22 | ||
8 | Software | Provide software upgrading during the whole life cycle | |
9 | Communication | Equipment uses RJ-45 interface which can ensure the stability and real-time for the remote data collection. | |
10 | Equipment maintenance | Calibrate once per year and non-professionals should not open the crate. Check the contact in a certain time to avoid poor contact. | |
11 | Dimension | (width)*(depth)*(height) mm | |
12 |
Test environment |
380V/50Hz
Power:9.6KW Work mode Continuous Work environment:-20—40 none dewfall Environment humidity: 10%~90% |
|
13 |
Ground load-bearing |
≤500Kg/M2 |