Semco SI BCDS 120V 30A 18CH – SLB

Semco SI BCDS 120V 30A 18CH – SLB

Technical Specifications

Specification:

▲Voltage: 12-120V DC

▲Current: 30A/60A/100A/200A DC

▲Number of channels: 18CH (with Cabinet)

▲Isolation of input and output

▲4U chassis size

 

Advantages and characteristics:

▲Modular design, single-point control technology, convenient expansion, high production and maintenance efficiency;

▲Battery cycle life test

▲Battery charge/discharge characteristic test

▲Battery charge retention ability test

▲Battery charge/discharge efficiency test

▲Battery overcharge/over discharge rate endurance test

▲Support CAN communication to realize data docking with BMS

▲Support docking with MES system

▲Auxiliary channel acquisition and recording

▲Static test, dynamic test, standstill

▲With anti-reverse connection, data loss protection function

▲Support multi-channel parallel connection

▲92% feedback efficiency

▲Charge and discharge power factor 0.99 (Rated Power)

Test Function:

 

Technical Specification:

Device model Semco SI BCDS 120V 30A 18CH – SLB communication method TCP/IP (network port)
Discharge voltage DC120V~12V Charging voltage DC12~120V
Charge and discharge current 120VSeries: 30A 60A 100A 200A
Number of channels 18 channels 6 channels 3 channel 1 channel
Voltage accuracy ±0.1% of FS Current accuracy ±0.1% of FS
Power accuracy ±0.1% of FS Time accuracy 1s/H
Current rise/fall response 10ms (10%-90%) Current response time 10ms
Output DC voltage resolution 0.01V
Output DC current resolution 0.01A Main channel data acquisition cycle 100ms
Input (AC) INPUT
Phase 3Φ4W Voltage 380V±10%
Frequency 47Hz-63Hz THD ≤3%
Power factor PFC 0.99 (rated power) Feedback efficiency 92% (rated power)
Power resolution 0.1W
Number of steps in a step file 250 steps, 10 layers can be nested
Cycles 1~9999 times
 

Data export method

Data can be derived into EXCEL, TXT, chart files, and can provide charge and discharge curves, capacity decay rate, cycle life curve, charge and discharge voltage, current, capacity-time and other data analysis curves and data lists
Data storage method The user can customize the name and data saving path, and the data is saved as a file
 

Main channel working mode

Charging: constant current charging CC, constant voltage charging CV, constant power charging CP, constant current and constant voltage charging CCCV, the conversion during constant current and constant voltage charging needs to achieve no impulse voltage current; Discharge: constant current discharge CD, constant power discharge CP, constant resistance discharge CR, constant voltage discharge CV; stand still

 

Constant current charging Battery pack voltage, time, capacity, power, cell temperature, cell voltage, cell voltage difference, RSOC, -∆V up
Constant voltage charging Current, time, capacity, power, cell temperature, cell voltage, cell voltage difference, RSOC, -∆V up
Constant current and constant voltage charging Current, time, capacity, power, cell temperature, cell voltage, cell voltage difference, RSOC, -∆V up
Put aside Time is up
Constant current discharge Battery pack voltage, time, capacity, power, cell temperature, cell voltage, cell pressure difference
Constant power discharge Battery pack voltage, current, time, capacity, power, cell temperature, cell voltage, cell pressure difference
Constant resistance discharge Battery pack voltage, current, time, capacity, power, cell temperature, cell voltage, cell pressure difference
Input protection Overvoltage, overcurrent, phase loss, over temperature, protection alarm, islanding effect protection;
Output protection Overvoltage, overcurrent, short circuit, capacity, temperature, cell overvoltage, cell under voltage protection; no output when the battery voltage is not detected;
Power failure protection After the external power is cut off, the battery and the device are automatically disconnected, effectively avoiding the problem of re-powering on
Hardware protection Power failure protection, open circuit protection, short circuit protection; battery connection reverse, wrong connection protection, over current protection, over voltage protection, over temperature protection
Short circuit protection External short circuit
 

Software protection

Power failure data protection, incoming call connection, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over- temperature protection, voltage trend abnormal protection, current trend abnormal protection, current

Abnormal fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage rising speed protection, abnormal discharge current falling speed protection

Alarm function The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, automatic load connection and disconnection, etc.
Cycles Max 10000 times
Way of working continuously working
 

Test environment

1.  Working method: continuous

2.  Working environment: -10C~50C

3.  Ambient humidity: 10%~90%

 

×
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors