Semco SI BCDS 100V 30A 6CH/120V 30A 6CH- SLB

Semco SI BCDS 100V 30A 6CH/120V 30A 6CH- SLB

Specification

  • Voltage: 10-100V DC
  • Current: 30A/60A/100A/200A DC
  • Number of channels: 6CH/3CH/2CH/1CH
  • Isolation of input and output
  • 4U chassis size

Advantages and features:

  • Modular design, single-point control technology, convenient expansion, high production and maintenance efficiency;
  • Battery cycle life test
  • Battery charge/discharge characteristic test
  • Battery charge retention ability test
  • Battery charge/discharge efficiency test
  • Battery overcharge/over discharge rate endurance test
  • Support CAN communication to realize data docking with BMS
  • Support docking with MES system
  • Auxiliary channel acquisition and recording
  • Static test, dynamic test, standstill
  • With anti-reverse connection, data loss protection function
  • Support multi-channel parallel connection
  • 92% feedback efficiency
  • Charge and discharge power factor 0.99 (rated power)

Test function

Device model SLB 100 30 Communicationmethod TCP/IP (network port)
Discharge voltage DC100V~10V Charging voltage DC10~100V
Charge and discharge current 100VSeries: 30A 60A 100A 200A
Number of channels 6 channels 3 aisle 1 aisle 1 aisle
Voltage accuracy ±0.3% of FS Current accuracy ±0.3% of FS
Power accuracy ±0.1% of FS Time accuracy 1s/H
Current rise/fall response 10ms (10%-90%) Current response time 10ms
Output DC voltage resolution 0.01V
Output DC current resolution 0.01A Mainchanneldataacquisition

cycle

100ms
Phase 3Φ4W Voltage 380V±10%
Frequency 47Hz-63Hz THD ≤3%
Power factor PFC 0.99 (rated power) Feedback efficiency 92% (rated power)
Power resolution 0.1W
Number of steps in a step file 250 steps, 10 layers can be nested
Cycles 1~9999 times
 

Data export method

Data can be derived into EXCEL, TXT, chart files, and can provide charge and discharge curves, capacity decay rate, cycle life curve, charge and discharge voltage, current, capacity-time and other data analysis curves

and data lists

Data storage method The user can customize the name and data saving path, and the data is

saved as a file

 

 

 

 

Main channel working mode

Charging: constant current charging CC, constant voltage charging CV, constant power charging CP, constant current and constant voltage charging CCCV, the conversion during constant current and constant voltage charging needs to achieve no impulse voltage current; Discharge: constant current discharge CD, constant power discharge CP, constant resistance discharge CR, constant voltage discharge

CV; stand still

Constant current charging Battery pack voltage, time, capacity, power, cell temperature, cell voltage,

cell voltage difference, RSOC, -∆V up

Constant voltage charging Current, time, capacity, power, cell temperature, cell voltage, cell voltage

difference, RSOC, -∆V up

Constant current and constant

voltage charging

Current, time, capacity, power, cell temperature, cell voltage, cell voltage

difference, RSOC, -∆V up

Put aside Time is up
Constant current discharge Battery pack voltage, time, capacity, power, cell temperature, cell voltage,

cell voltage difference

Constant power discharge Battery pack voltage, current, time, capacity, power, cell temperature, cell

voltage, cell pressure difference

Constant resistance discharge Battery pack voltage, current, time, capacity, power, cell temperature, cell voltage, cell pressure difference
Input protection Overvoltage, overcurrent, phase loss, overtemperature, protection alarm,

islanding effect protection;

Output protection Overvoltage, overcurrent, short circuit, capacity, temperature, cell

overvoltage, cell undervoltage protection; no output when the battery voltage is not detected;

Power failure protection After the external power is cut off, the battery and the device are automatically disconnected, effectively avoiding the problem of re- powering on
Hardware protection Power failure protection, open circuit protection, short circuit protection; reverse battery connection, wrong connection protection, over current

protection, over voltage protection, over temperature protection

Short circuit protection External short circuit
 

 

Software protection

Power failure data protection, incoming call connection, over- voltage and over-discharge protection, over-current and under- current protection, capacity protection, over-temperature protection, voltage trend abnormal protection, current trend
abnormal protection, current

Abnormal fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage rising speed protection, abnormal discharge current falling speed protection

Alarm function The hardware has functions such as emergency cut-off switch, automatic

shutdown after power failure, automatic load connection and disconnection, etc.

Cycles Max 10000 times
Way of working Continuously working
Test environment Working method: continuous Working environment: -10C~50C Environmental humidity: 10%~90%

 

×
Generic selectors