Semco SI BCDS 100V (10/20A) (2kW) 7CH

Semco SI BCDS 100V (10/20A) (2kW) 7CH

It is mainly used for charging and discharging cycle tests of finished lithium battery packs. The test items include: battery charging voltage protection, discharge voltage protection, capacity, etc. It has charging testing, discharging testing, and Loop test Functions. By editing the steps of the plan, the battery can be tested according to the set process.

Our Gallery

Router: Used for connecting LAN connection with system.

Battery Cabinet: To insert the battery pack.

Screen: Give real time address for charging and discharging channel.

Power switch: Used for power supply ON/OFF for the machine.

Ethernet Switch: Used for multiple LAN input output connection

Ports: Power Supply & Communication Probes Connector for channels.

Application It is used for charging and discharging of battery pack or to find the age of a battery pack.
Video link https://youtu.be/uNDc7W2lN7c

After sale service

  • One year warranty with lifetime support (With AMC Policy)
  • Online support, Video technical support.
  • We will guarantee the quality of the machine, and perform a test on the machine before leaving the warehouse to ensure that each set of equipment runs well, and provide long-term after-sales service up to 100% customer satisfaction.

Technical Details:

 

Semco Battery Charge & Discharge Cabinets
Model Semco 100V (10/20A) (2kW/CH) 7CH
Input power AC 220V ±10% / 50Hz
Voltage Measuring range 9~100V
Precision ± (0.2% of reading + 0.2% of range)
Current Charging range 50~10000mA
Charging accuracy ± (0.2% of reading + 0.2% of range)
Discharge range 50~20000mA
Precision ± (0.2% of reading + 0.2% of range)
Recharge Constant voltage Cut-Off Current 50mA minimum
Capacity Precision ±1‰
Power Discharge power ≤1400W
Time Inspection time Receive real time <2S
Timing range 0~999 hours/step
Data logging interval ≥5S
Mid-range version 1.1 series
Recharge Charging mode Constant current and constant voltage charging
Cut-off condition Voltage, current, relative time,

overcharge protection

Discharge Discharge mode Constant current discharge
Cut-off condition Voltage, relative time, over-discharge protection
Loop Cycle measurement range 1~999 times
Number of steps in a single cycle 100
Voltage and current detection sampling Four-wire sampling
Database Use SQL database to manage test data
Host computer communication method Based on TCP/IP protocol, serial port
Data output method EXCEL, TXT, chart
Communication interface Network port
Number of channels per

cabinet

7Channel, 7Line 1Column
Chassis size W*D*H:600*450*170(mm)
Cabinet size W*D*H:1130*600*1820(mm)
Battery space size W*D*H:370*600*170(mm)
Number of modules Support up to 7 channels
Weight 250 kg

 

×