SLB 5V 60A 8CH

SLB 5V 60A 8CH

1. Technical Parameters

Item Technical parameters
Model SLB 5V 60A 8CH
Channel number 8CH
Control method Independent control for each channel, current and voltage four-wire system collection
Characteristics Constant current source and constant voltage source, double closed loop structure
Input resistance ≥1MΩ
 

Voltage

 

Range

Charge 10mV-5V ( tester port )
Discharge 1V-5V( tester port ),The minimum discharge voltage is related to the line length
Precision ±0.1% of FS, Ambient temperature 15℃-35℃
 

Current

 

Range

Charge 120mA-60A
Discharge 120mA-60A
Precision ±0.1% of FS, Ambient temperature 15℃-35℃
 

Power

Single channel 300W
Stability 0.2% of FS
Time ≤10ms (Current response time)
 

Data record

Frequency 1Hz
 

Data recording conditions

Minimum time interval:1S
Minimum voltage interval:1mV
Minimum current interval:1mA
 

Charge

Charging mode Constant current charging, constant voltage charging, constant current constant voltage charging, constant power charging
Cut-off condition Voltage, current, relative time, capacity, -△V
 

Discharge

Discharge mode Constant current discharge, constant power discharge, constant resistance discharge
Cut-off condition Voltage, current, relative time, capacity, -△V
 

Pulse mode Optional

Charge Constant current mode, constant power mode
Discharge Constant current mode, constant power mode
Minimum pulse width Recommended above 5S
Cut-off condition Voltage, relative time
Item Technical parameters
DCIR Optional Support custom pick points for DCIR calculation
 

Cycle

Loop test 199 commands can be set, 65535 cycles can be set
Loop nesting Support 5 levels of loop nesting
 

 

 

Protection

 

 

 

Software protection

Support power-down data protection
Support continuous start (the computer should have UPS power)
Overvoltage protection, under voltage protection, capacity protection, overcurrent protection, undercurrent protection
Anti-reverse protection
Data export method Excel, PDF
cooling method Wind cooling
Equipment noise ≤60dB
Communication RJ45 network port communication
Dimensions
Display screen
System Requirements Windows XP and above

2. Environment Requirements

Item Technical parameters
Working temperature 0℃-40℃
Storage temperature -10℃-65℃
Relative humidity of working environment ≤70% RH (No condensation)
Relative humidity of storage environment ≤80% RH (No condensation)
Input active power 2700W
Input power AC220V±10%/50Hz,Other power specifications are optional
Fixture type
Other requirements

 

×
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors